All In One Solar Power System 51.2v

BND-AIO62-61(A)HFSP
· Easy Installation
· One-person installation
· Easy power output expansion
· Without cable connection, plug in & out

· Safety and Reliability
· High cycle stability and long lifespan
· Whole system warranty

· Smart 0&M
· Auto under-voltage wakeup
Delivery
EXW
minimum order
30 pieces
Supply Ability
1000000000pieces / Month
Stock Time
45Day
Quantity:
Contact Now
add to cart
Buy Now
ModelBND-AIO62-61(A)HFSP
Main Parameter
Battery ChemistryLiFePO4
Capacity(Ah)120
ScalabilityMax. 16 pcs in Parallel
Nominal Voltage(V)51.2
Operating Voltage(V)43.2~57.6
Energy (kWh)6.14
Charge/ Discharge Current (A)
Recommend50
Max.100
Peak120 (30s,25℃)
Dimension (mm)630*250*415
Weight Approximate(kg)≈60
Master LCD Indicator4LED(SOC:25%~SOC100%),2LED(working,alarming),LCD
IP Rating of EnclosureIP20
Operating TemperatureCharge:0~+55℃/Discharge:−20℃~+55℃
Storage Temperature0℃~+35℃
Humidity5%~95%
Altitude≤2000m
Cycle Life≥6000(25℃±2℃,0.2C/0.2C,70%EOL)
InstallationWall–Mounted/Floor standing
Communication PortCAN,RS485,RS232
Warranty Period5 years
CertificationUN38.3,CE
Inverter SpecificationBND-MAS5548(A)HF
Input
PhaseL+N+PE
Nominal Voltage220/230/240VAC
Voltage Range90-280VAC±3V(Normal Mode)170-280VAC±3V(UPS Mode)
Frequency Range50Hz/60Hz(Adaptive)
Output
Rated Power5500W
Output Voltage(AC)220/230/240VAC±5%
Output Frequency50/60Hz±0.1%
WaveformPURE SINE WAVE
Transfer Time(Optional)≤10ms(UPS mode)/≤20ms (INV mode)
Peak power10000VA
OverloadBattery Mode:
1min@102%~110% Load
10s@110%~130% Load
3s@130%~150% Load
200ms@>150% Load
Peak efficiency (battery mode)>94%
charger
PV charging methodMPPT
PV max input power5500W
MPPT tracking range120~500Vdc
Max PV input voltage500Vdc
Max PV charging current100A
Max AC charging current60A
Max charging current100A
Display
LCD displayOperating mode/load/input/output, etc.
Environmental parameters
Operating environment temperature0~40°C
Operating environment humidity20%~95% (Non condensing)
Storage temperature-15-60°C
AltitudeThe altitude should not exceed 1000m, derating above 1000m, up to 4000m
noise≤50db
Certification
CertificationEN-IEC 60335-1, EN-IEC 60335-2-29, IEC 62109-1